Carbon Dioxide Gas Detector Co2 Monitor Analysis Alarming Device

Carbon Dioxide Gas Detector Co2 Monitor Analysis Alarming Device

  • Description
  • Inquiry

Feature

1. Using imported high-precision sensor, can simultaneously detect two, three or four gas

2. LCD dot matrix display technology

3. English operation interface

4. Gas concentration measurement units PPM, mg/m3 can quickly switch

5. Built-in micro sampling pump

6. Explosion-proof grade: Exia II CT4

 

Function

1. Monitoring the concentration of gas in a confined space and alarm

2. With self-check function, zero calibration function

3. One key to restore the factory settings can be removed misuse problems

4. With temperature and pressure compensation, the compensation can achieve the perfect temperature and pressure environments under different gas concentrations

5. Two grade sound and light alarm, alarm point can be set

6. Large-capacity lithium polymer rechargeable battery

7. Pump suction sampling method, adjustable

8. The shell is made of high-strength plastic, non-slip, waterproof, dustproof, explosion

9. Exquisite aluminum suitcase

 

Application

1. Petrochemical, industrial production, refining forging, electricity, coal, engineering, environmental monitoring, wastewater treatment

2. Pharmaceutical, household and environmental protection, animal husbandry, greenhouse cultivation, storage and logistics, brewing fermentation, agricultural production

3. Fire, gas, building construction, municipal enterprises, school laboratories, research centers

 

 

Parameter:

Gas Detected Carbon Dioxide Co2
Detection principleElectrochemistry
Sampling MethodPumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Measure Range0-1ppm, 5ppm, 10ppm, 20ppm, 50ppm, 100ppm, 500ppm, 1000ppm, 5000ppm
Resolution0.001ppm, 0.01ppm, 0.1ppm, 1ppm
Precision≤± 2-3% F.S for normal sensor, .≤± 1% F.S for high precision sensor
Signal OutputHigh-speed data transmission by USB, available for data downloading and

printing (optional)

Response Time≤10SRecovery Time≤10S
Repeatability≤±1%Linearity error≤±1%
Zero shift≤±1%(F.S/year)DisplayLCD dot matrix display
Operating languageChinese/EnglishGas unit%LEL, PPM
Temperature-20℃~50℃Humidity0-95%RH
Explosion-ProofII 2G Ex ia IIC T4 Ga IP66Degree of protectionIP66
Alarm modeSound, light, vibrationOperating time12h
Dimensions205*75*32mmWeight300g

Contact Us